Part Number Hot Search : 
D10XB20H X84C1 MAX48 ZMC2V4 1N5346B MA4AG HMC10 A1601
Product Description
Full Text Search
 

To Download MPB150 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 MPB150 Dual-Output AC-DC Series Data Sheet
Features * RoHS compliant for all six substances * High power density in an industry-standard 3" x 5" footprint * Power Factor Correction (PFC) meets EN61000-3-2 * Main output remote sense * Power Good signals * CE marked to Low Voltage Directive * Input transient & ESD compliance to EN61000-4-2/-3/-4/-5
Description The MPB150 Series incorporates patented high efficiency circuitry, high power density and active Power Factor Correction (PFC) to meet the requirements of networking and data communications systems, as well as commercial and industrial configurations. MPB150's deliver a regulated main output plus a second 12V output for fans or other system functions. The MPB150 is rated for convection as well as forced-air cooling. Full output power is available with as few as 15 Cubic Feet per Minute (CFM) forced-air cooling. The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.
Model Selection
MODEL OUTPUT VOLTAGE (VOLTS) MAXIMUM OUTPUT CURRENT (AMPS), 130 LFM TOTAL REGULATION % RIPPLE & NOISE % pk-pk (NOTE 1) REGULATION RANGE
MPB150-2012G
(NOTE 2, 3, 4)
MPB150-2024G
(NOTE 2, 3, 4)
MPB150-2048G
(NOTE 2, 3, 4)
+12V 12V +24V 12V +48V 12V
12.5A 0.5A 6.0A 0.5A 3.1A 0.5A
3% 5% 3% 5% 3% 5%
1% 1% 1% 1% 1% 1%
11.64V to 12.36V 11.40V to 12.60V 23.28V to 24.72V 11.40V to 12.60V 46.56V to 49.44V 11.40V to 12.60V
NOTES: 1) 2) 3) 4)
Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. Maximum forced-air output power is 150 watts with 15 CFM airflow. Maximum convection output power is 70 watts. V2 is isolated from V1 and can be used as a negative or positive output.
APR 28, 2006 revised to JAN 24, 2007
Page 1 of 4
www.power-one.com
MPB150 Dual-Output AC-DC Series Data Sheet
Input Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Input Voltage- AC Input Frequency Brownout Protection Hold-up Time Input Current Input Protection Inrush Surge Current Power Factor Circuitry Operating Frequency
Continuous input range. AC Input. Lowest AC input voltage that regulation is maintained with full rated loads. Over full AC input voltage range at full rated load. 90 VAC at full rated load. Non-user serviceable internally located AC input line fuse, 250 VAC, 3.15A. Internally limited by thermistor, 110VAC: one cycle, 25 C. 220VAC: Active PFC meets requirements of EN61000-3-2. Switching frequency of main transformer.
90 47 90 17
264 63
2.2 23 46 45
VAC Hz VAC ms ARMS APK kHz
Output Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Efficiency Minimum Loads Ripple and Noise Output Power (Note 1) Overshoot /Undershoot Regulation Transient Response Turn-on Delay Turn-on Rise Time
Full Load, 230VAC. Varies with distribution of loads among outputs. V1 load for full regulation on V2. All models operate at no load without any damage and meet all specs on V1 above 0 amps. Full load, 20 MHz bandwidth. At 15 CFM forced-air cooling. See Application Note for details. Convection: Consult Factory. Output voltage overshoot/undershoot at turn-on. Varies by output. Total regulation includes: line changes from 85-132 VAC or 170-264 VAC, changes in load starting at 20% load and changing to 100% load. Maximum deviation due to a 25% load change with unit at 75% load. Time required for initial output voltage stabilization. Time required for output voltage to rise from 10% to 90%.
75 5
80
85
% Watts
See Model Selection Chart 150 10 See Model Selection Chart 3 0.2 0.2 1.5 20
Watts %
% Sec ms
Interface Signals and Internal Protection
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Overvoltage Protection
Overload Protection Remote Sense (Note 1) Power Good Signal
MPB150-2012 13.5 MPB150-2024 26.9 MPB150-2048 57.6 Fully protected against output short circuit or overload. Automatic recovery upon removal of overload condition. Total (+sense and -sense) voltage compensation for cable losses. AC/DC indicator - This signal indicates the status of the AC input or DC outputs. When there is sufficient AC voltage and the outputs are operating normally, an open collector signal is provided. Turn-On delay time from application of AC: 50 Warning time before outputs go out of regulation: 5 Warning time before outputs deviate 10% from the nominal value: 15 Sink Current Pull-up Voltage Provided on dual-output models. Open collector signal intended to drive an LED. Closed collector occurs when the Power Good Signal is in its open collector state. Sink Current Pull-up Voltage Protected against overtemperature conditions. Unit recovers when overtemperature condition is removed. Up to 4 units can be connected in parallel. There are some limits for parallel operation. See Applications Note. N+1 redundancy is provided. V2 needs an external isolation diode for N+1 operation. Internal isolation diode is provided on V1.
V1 output.
16.5 31.1 62.4
VDC
500
mV
500 ms 20 30 mA V
Power Supply OK Signal
20 30
mA V
Thermal Shutdown Current Share
Isolation Diode
NOTES: 1) Negative (-) sense must be connected to output common or load common for proper power supply operation.
APR 28, 2006 revised to JAN 24, 2007
Page 2 of 4
www.power-one.com
MPB150 Dual-Output AC-DC Series Data Sheet
Safety, Regulatory, and EMI Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Agency Approvals
Dielectric Withstand Voltage Electromagnetic Interference ESD Susceptibility Flicker Radiated Susceptibility EFT/Burst Input Transient Protection RF Immunity Magnetic Fields Voltage Dips Insulation Resistance Leakage Current
UL60950-1. CSA 22.2 No. 60950-1. (Approvals Pending) EN60950 (TUV). IEC60950-1. AC to chassis. 1500 Input to output. 3000 EN55022 Conducted. Class A 6 Per EN61000-4-2, Level 4 8 Per EN61000-3-3. Per EN61000-4-3. 3 Per EN61000-4-4. 1 Per EN61000-4-5, Level 3, 2 kV (Line-to-Gnd) minimum, 1 kV (Line-to-Line) minimum. Per EN61000-4-6. 0.15 to 80 MHz (1 kHz sinewave) 3 Per EN61000-4-8. 1 Per EN61000-4-11. Input to output. 10 Per EN60950 (264 VAC) 1.0
VAC VDC dB kV V/m kV V/m A/m M mA
Environmental Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Altitude Operating Temperature Storage Temperature Forced-Air Cooling
Operating Non-Operating Derate linearly from 50 to 70C to 50% power at 70C. At 100% load: MPB150 models will operate at -20C, but will not meet all specifications. Forced-air cooling of 15 CFM is required for full output power. Air velocity is measured with power supply mounted on 0.375" (9.5mm) standoffs. Airflow direction is from the input section to the output section. See Application Note for details. Included in total regulation of outputs. Non-Condensing. Operating: 11 3ms, 3 axes, Half Sine. Non-operating: 11 3ms, 3 axes, Half Sine. Operating: Random vibration, 5-500 Hz, 10 minutes each axis. Non-Operating: Random vibration, 5-500 Hz, 10 minutes each axis.
0 -40
10K 50K 50 85
ASL Feet C C
Temperature Coefficient Relative Humidity Shock Vibration
5
85 15 40 2.4 6.0
%RH Gpk GRMS GRMS
APR 28, 2006 revised to JAN 24, 2007
Page 3 of 4
www.power-one.com
MPB150 Dual-Output AC-DC Series Data Sheet
Mechanical Drawing (-2012G, -2024G, & -2048G Models)
WEIGHT:
J 1 - A C INPUT CONNECTOR Pin 1 Pin 2 Pin 3 NEUTRAL N O PIN LINE 5.00" (127.0) 4.55" (115.57) O 0.16" (4 PL) (4.06)
0.63 lb. (0.3 kg)
J2 Pin Pin Pin Pin Pin Pin J3 Pin Pin Pin Pin Pin Pin J4 Pin 1 Pin 2 1 2 3 4 5 6 1 2 3 4 5 6
J 2 - V 1 DC OUTPUT CONNECTOR
TOP VIEW
PIN #1
MPB150 -2012G +12V +12V +12V RTN RTN RTN
-2024G +24V +24V +24V RTN RTN RTN
-2048G +48V +48V +48V RTN RTN RTN
3.00" 2.78" (76.2) (70.6) 2.56" (65.02) PIN #1
PIN #1 J3- SIGNAL CONNECTOR PIN #1 J4- V2 DC OUTPUT CONNECTOR FASTENER CLEARANCE AREA (4 PL)
RTN - SENSE + SENSE CURRENT SHARE POWER GOOD POWER SUPPLY OK
SAFETY GROUND CONNECTION POINT
SCREWS SHOWN FOR REFERENCE ONLY
0.06" (1.5)
+12V +12V RTN
1.25" (31.75)
1.00" (25.4)
PRINTED
CIRCUIT
BOARD
SIDE VIEW
0.19" (4.8)
END VIEW
Mating Connectors
NOTE: Part numbers are MOLEX; equivalents are acceptable.
MPB150 -2012G -2024G -2048G 09-50-8031 08-52-0113 09-50-8061 08-52-0113 22-01-3067 08-50-0114 22-01-3027 08-50-0114
J1 J2 J3 J4
Housing Pins Housing Pins Housing Pins Housing Pins
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice.
APR 28, 2006 revised to JAN 24, 2007
Page 4 of 4
www.power-one.com


▲Up To Search▲   

 
Price & Availability of MPB150

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X